Naslov (srp)

Komparativna analiza kliničkih i biomehaničkih parametara hiruškog lečenja trohanternih preloma primenom samodinamizirajućeg unutrašnjeg fiksatora i gama klina

Autor

Mitković, Milan M., 1982-, 35683687

Doprinosi

Milenković, Saša 1965-
Micić, Ivan
Manić, Miodrag
Ristić, Branko
Starčević, Srđan

Opis (eng)

In the clinical part of the study results of trochanteric fractures surgical treatment were analysed in 67 patients treated at the Clinic for Orthopedics and Traumatology of Clinical center Niš, using two different methods of internal fixation: intramedullary gamma nail fixation (Gamma Nail - GN) and extramedullary fixation with Self-dynamisable Internal Fixator with 2 sliding screws (Self-dynamisable Internal Fixator - SIF). Comparison of these two methods was performed in terms of the following clinical parameters: operative time, intraoperative fluoroscopy time, intraoperative and postoperative infusion and transfusion, time of hospitalization, hip function and health-related quality of life at least 2 years after surgery. There were significantly higher values of operative time, intraoperative fluoroscopy time and amount of intraoperative infusion in the GN group compared to the SIF group, suggesting appropriate differences in the number of daily operations planned, in requirement of operating room staff protection from intraoperative x-ray and in planning the required intraoperative infusion. There was no significant difference between SIF group and GN group regarding the other clinical parameters mentioned. There can be concluded that application of GN and application of SIF with 2 sliding screws require the same amount of transfusion and same time of hospital stay, as well as providing the same final clinical result in the treatment of trochanteric fractures. In the laboratory part of the study, the axial forces required to initiate the dynamization of the sliding screws, during the transversal load of these screws, was measured and analysed for GN, SIF with 2 sliding screws and SIF with cannulated sliding screw. Regression parameters of the dependence between the forces required to initiate sliding screws dynamization and the bending moments of their transverse load were calculated afterwards. Increasing of force required to initiate dynamisation by increase of the bending moment was found to be highest for SIF with 2 sliding screws, then for gamma wedges, and the lowest was for SIF with a cannulated sliding screw. Regarding laboratory results, there can be concluded that, in the moment of weight bearing on the operated leg, the initiation of sliding screw dynamisation will not be realized in patients with higher values of body weight or femoral neck length. Thus, it is recommended to perform frequent movements in the operated hip without full weight bearing at the first postoperative rehabilitation time in these patients.

Opis (srp)

Biografija: list 145;Bibliografija: listovi 124-140. Datum odbrane: 07.02.2020. Orthopaedic Surgery and Traumatology

Jezik

srpski

Datum

2019

Licenca

Creative Commons licenca
Ovo delo je licencirano pod uslovima licence
Creative Commons CC BY-NC-ND 2.0 AT - Creative Commons Autorstvo - Nekomercijalno - Bez prerada 2.0 Austria License.

http://creativecommons.org/licenses/by-nc-nd/2.0/at/legalcode